Free Shipping on All Orders
Zone Air HVAC Mini Split - Professional HVAC, DIY Prices
(801) 882-2324

Zone Air® Airframe 3 ZONE 36,000 BTU (12K+12K+12K) 24 SEER2 230V Ceiling Cassette Mini-Split Heat Pump System with 3x Pre-Charged Linesets - Up to 1,800 Sq Ft

$5,599.99$7,299.99
Save $1700 (23% OFF)
Or as low as $467/mo with Affirm
Zone Air customers saved over $3,000 on average with our DIY units in 2025, compared to contractor installation.
USA based testing, inspection, and final assembly

At a Glance

Power: 208-230V / 30A, dedicated circuit, electrician recommended
Room size: Up to 1,800 sq ft in mild climates
Install: DIY install, pre-charged quick connect systems mean no vacuum pump or contractor needed
Lineset: 3x 16 ft pre-charged included, each can be extended up to 50 ft (custom lengths available)
Room size varies by climate, insulation, and window exposure. Use our calculator for an exact recommendation. Do not use an extension cord.
Free shipping · Estimated delivery: Thursday, Aug 6

Choose your lineset lengths

One pre-charged lineset per zone — 3 included at 16 ft. Pick a longer run for any zone that needs it.

Zone 1

Zone 2

Zone 3

Frequently Purchased Together

0
Lineset Cover Kit
16 ft. Decorative Lineset Cover
Hide exposed lines — paintable PVC · up to 3
$99.99
Mounting Bracket
Wall Mount Bracket
Heavy-duty, holds up to 550 lbs
+$109.99
1
Secure checkout • SSL encrypted • Satisfaction guaranteed
Zone Air Guarantee

5 year parts, 7 year compressor warranty — 30 day returns — Live US support 9–5 MST

Payment & Security

VisaMastercardAmexApple PayDiscoverGoogle PayPayPalShop Pay

Your payment information is processed securely. We do not store credit card details.

System Overview

36,000 BTU
Capacity
208-230V / 30A
Power
24 SEER2
Efficiency
Independent zone control
Cold climate performance
30 dB per unit
Sound
Up to 1,800 sq ft
Max room size

Your Purchase Includes

Everything you need for a complete DIY installation

Indoor Unit
3x Indoor Air Handlers
Outdoor Condenser
Outdoor Condenser
Pre-Charged Lineset
Pre-Charged Linesets
Installation Kit
Installation Kit
Remote Control
3x Remote Controls

Summary

  • Voltage: 208-230V
  • Environmentally friendly R454B (pre-charged)
  • Low ambient range operation: heating down to Independent zone control
  • Variable-speed DC inverter driven performance
  • Pre-charged lineset included for DIY installation
  • Energy Star certified

Technical Information & Performance

SYSTEM KIT

Connected Indoor Capacity36,000 BTU/h (3× 12,000)
Per Zone Capacity12,000 BTU/h each
Outdoor Unit Rated Cooling Capacity27,000 BTU/h (4,500-31,000 range)
Outdoor Unit Rated Heating Capacity28,000 BTU/h (4,500-33,000 range)
SEER2 Rating24
EER2 Rating12.0
HSPF2 (Region IV/V)10.5 / 8.8
Voltage208-230V / 60Hz
Breaker Needed30A (double-pole)
Number of Zones3
Refrigerant TypeR454B (pre-charged)
Indoor Units3× ceiling cassette units (24" × 24")
Air Distribution4-way (360°) per unit
Linesets Included3× 16 ft pre-charged
Operating Temperature-13°F to 131°F
Sound Level (per unit)28–42 dB
Outdoor Sound Level62 dB(A)
Outdoor Unit Dimensions (WxDxH)38-1/2" x 16-1/2" x 31-5/8"
Outdoor Unit Weight119 lbs
Condensate PumpsIntegrated in each unit

INDOOR UNIT

Part Numberzdiy-cc-12I
Net Dimensions (WxDxH)25-5/8" x 25-5/8" x 22-1/2"
Carton Dimensions (WxDxH)Coming soon
Net / Gross WeightComing soon

OUTDOOR UNIT

Part Numberzdiy-cc-27O
Breaker Needed30A (double-pole)
Net Dimensions (WxDxH)38-1/2" x 16-1/2" x 31-5/8"
Sound Level62 dB(A)
Carton Dimensions (WxDxH)Coming soon
Net / Gross Weight119 lbs
Zone Air® Product Series

Airframe Ceiling Cassette Series

Zone Air® ceiling cassette systems provide 360-degree airflow from a flush-mounted ceiling unit. Ideal for offices, commercial spaces, and modern homes where wall space is limited. Each system includes a decorative panel, pre-charged lineset, and full installation hardware.

Quick-connect lineset installation

0:00 / 0:00

Product Warranty

Coverage applies to the original purchaser with proof of purchase. See our Warranty Policy.

  • 5 years warranty on parts
  • 7 years warranty on compressor

Manuals & Documents

360° Air Distribution

Even Temperature Throughout

360° Air Distribution

Four-way distribution eliminates hot and cold spots, spreading conditioned air evenly throughout the entire space.

Year-Round Comfort

Smart Louver Control

Intelligent louvers auto-adjust: 10° angle for gentle cooling, 85° angle to push warm air downward in heating mode.

Smart Louver Control
Wi-Fi Smart Control

Control From Anywhere

Wi-Fi Smart Control

Control from anywhere with the Zone Air app. Adjust temperature, set schedules, and monitor energy usage from your phone.

Simple Upkeep

Easy Filter Access

Panel drops down for quick access to washable, reusable filters. No tools required.

Easy Filter Access

Advanced Features

Smart Climate Control

  • Independent zone control
  • 360° air distribution per zone
  • 24-hour programmable timer
  • Turbo mode for rapid cooling/heating
  • Auto mode with intelligent temperature control
  • ECO mode for energy savings

Premium Components

  • High-efficiency rotary compressor
  • Premium indoor motors
  • 4-speed variable fan control
  • R454B eco-friendly refrigerant
  • Fire-proof electrical enclosure
  • High-efficiency heat exchanger

Convenience & Safety

  • Auto-restart after power loss
  • Self-diagnostic system
  • Refrigerant leakage detection
  • Emergency manual operation
  • Ceiling panel indicator lights
  • Temperature display toggle (°C/°F)

Easy Maintenance

  • Drop-down panel for filter access
  • Washable air filters
  • Condensate pumps included
  • Self-cleaning function
  • Quick service access
  • Anti-cold wind protection

Operating Temperature Range

Indoor Temperature (Cooling)
62-89°F (17-31°C)
Indoor Temperature (Heating)
32-86°F
Outdoor Temperature (Cooling)
5-131°F (-15 to 55°C)
Outdoor Temperature (Heating)
-13 to 86°F (-25 to 30°C)

Three Zones of Invisible, 360° Comfort — Flush in the Ceiling

This 3 zone ceiling cassette mini split conditions three separate spaces — up to 1,800 square feet total — with nothing on the walls. Each 12,000 BTU Airframe cassette recesses flush into the ceiling and washes air in four directions at once, covering rooms evenly from the center instead of blowing from one wall. Every zone has its own thermostat, remote, and WiFi control.

All three linesets ship pre-charged with R454B refrigerant, so there is no vacuum pump, no gauges, and no EPA license in the install. The 27,000 BTU multi-zone condenser is rated 24 SEER2 with heating to -13°F, and integrated condensate pumps in each cassette handle drainage without gravity runs.

Why You'll Love It

  • 360° Air DistributionFour-way discharge from the center of the ceiling covers a room far more evenly than a wall unit blowing from one side — no hot corners, no drafts across the couch.
  • Completely Out of the WayCassettes sit flush in a drop ceiling or between joists. Walls stay clear for shelving, art, and sight lines — ideal for offices, restaurants, retail, and open-concept homes.
  • Three Independent ZonesEach cassette runs its own schedule and setpoint. Condition the conference room, showroom, and back office separately instead of arguing over one thermostat.
  • DIY-Friendly Multi-ZoneThree pre-charged quick-connect linesets mean the refrigerant circuit never opens. Cassette installs need ceiling access and a second set of hands, but no HVAC technician.
  • 24 SEER2 With Cold Climate HeatThe inverter condenser is rated 24 SEER2 and 10.5 HSPF2 and keeps heating down to -13°F.

What Makes It Different

Ceiling cassette multi-zone systems are usually contractor-only equipment: flared fittings, vacuum pulls on every circuit, and a refrigerant charge calculation per zone.

  • Pre-Charged, Quick-Connect CircuitsEach of the three linesets arrives factory-sealed with refrigerant inside. Thread the couplings by hand, torque to spec, and verify with soapy water.
  • Honest Capacity NumbersThree 12K cassettes connect 36,000 BTU/h of indoor capacity to a 27,000 BTU/h rated condenser — a standard multi-zone connection ratio, and both numbers are printed in the spec table below.
  • Built-In Condensate PumpsEvery cassette includes an integrated condensate pump, so drainage routes up and over to wherever it needs to go — no gravity drain planning.

How It Works

  1. Frame and Hang Three CassettesCut the ceiling openings, hang each cassette from the structure above, and clip on the flush trim panels.
  2. Run and Connect the LinesetsRoute the three pre-charged linesets through the ceiling to the outdoor unit, hand-thread the quick-connect couplings, torque to spec, and test each joint with soapy water.
  3. Power and PairWire the condenser to a dedicated 230V circuit (a licensed electrician is recommended for the disconnect), then pair each zone to the WiFi app.

Who It's For

This 3 zone cassette system is for:

  • Offices, restaurants, and retail spaces that need three independently controlled areas with nothing on the walls
  • Open-concept homes and finished basements with drop ceilings or accessible joist bays
  • Renovations where wall units would clash with the design
  • Building owners who want commercial-style comfort without a commercial installation contract

Only need two zones in the ceiling? The Airframe dual-zone cassette system covers two rooms.

Frequently Asked Questions

How much ceiling depth do the cassettes need?

Each Airframe cassette is a 24" × 24" unit designed to recess into a drop ceiling grid or between joists with adequate plenum depth. Confirm your ceiling cavity against the dimensions on the spec sheet before ordering.

How can a 27,000 BTU condenser support 36,000 BTU of cassettes?

Multi-zone systems use a connection ratio: the outdoor unit is rated 27,000 BTU/h while up to 39,000 BTU/h of indoor capacity may be connected, per the manufacturer spec sheet. Three zones rarely demand full capacity simultaneously, so the inverter compressor shifts output to the zones calling for it.

Do the cassettes need drain lines?

Each cassette has an integrated condensate pump, so condensate can be lifted and routed horizontally to a suitable drain point instead of relying on gravity.

Is this really a DIY install?

The refrigerant side is — all three linesets are pre-charged R454B with hand-tight quick-connect fittings, so no vacuum pump or EPA license is needed. Plan for ceiling access, a helper for lifting, and a licensed electrician for the 230V disconnect wiring.
View all FAQs

Ceiling Comfort in Three Zones

Three flush-mount cassettes, one condenser, three pre-charged linesets — commercial-grade zoning you can install yourself.

Free shipping. 30-day returns on uninstalled systems.